低放射性废物的人工检查准确性研究

Inspection of Low-Level Radioactive Waste

Human Factors The Journal of the Human Factors and Ergonomics Society · 1991
被引 3
ABS 3

中文导读

在两家核电站的三项研究中,测量了技术人员用手持探头分拣低放射性废物(干性活性废物)的准确性,发现漏检率在3%到38%之间,且误报率很高。

Abstract

The accuracy of manual inspection of low-level radioactive waste (called dry active waste, or DAW) was determined in three studies conducted at two nuclear power plants. The project was conducted to determine the level of sorting accuracy in work settings given existing procedures, equipment, and technician characteristics. The research paradigm employed in each of the three studies included an unmodified waste stream of roughly 10 000 items and sorting by radioactive waste technicians using hand-held probes. Sorting performance was measured unobtrusively by intercepting the outflow from sorting stations and verifying the radioactivity of each piece of trash with a prototype semiautomated sorting table. In all, more than 30000 items of trash were examined, classified, counted, and verified. The results showed that between 1% and 19% of all items in each of the three DAW waste streams were contaminated at levels ≥100 corrected counts per minute. Sixty-two percent of the contaminated items in Study 1,87% of the contaminated items in Study 2, and 97% of the contaminated items in Study 3 were detected during inspection. False positive rates were very high in all three studies. The production rates and accuracy obtained on the semiautomated plastic scintillation sorting table used during the verification stages of this project greatly exceeded the rates for manual sorting.

核能废物管理环境科学人因工程