用户调整警报阈值的复杂性

The Intricacies of User Adjustments of Alerting Thresholds

Human Factors The Journal of the Human Factors and Ergonomics Society · 2017
被引 12
ABS 3

中文导读

研究了用户能否正确调整警报阈值的问题,发现用户常因难以确定最优设置和收集必要信息而无法做出恰当调整,对系统设计者有参考价值。

Abstract

OBJECTIVE: We address the question of necessary conditions for users to adjust system settings, such as alarm thresholds, correctly. BACKGROUND: When designing systems, we need to decide which system functions users should control. Giving control to users empowers them, but users must have the relevant information and the ability to adjust settings correctly for their control to be beneficial. METHOD: Using the example of adjusting an alerting threshold, we analyze the conditions for when users can and when they cannot possibly adjust threshold settings adequately. RESULTS: We identify two obstacles that limit users' ability to adjust thresholds adequately: (a) the difficulty of determining the correct threshold settings, especially because of users' strong response to false positive indications, and (b) the difficulty of collecting the information necessary for setting the threshold. CONCLUSION: Users often cannot identify the optimal settings for a system, so it is unlikely that they choose adequate system settings. APPLICATION: System designers must consider the difficulties users face and analyze them explicitly when deciding on user involvement in processes.

人机交互系统设计警报管理用户控制