Comparative reliability, concurrent and convergent validity, and predictive value of the 6-min walk test over 15 and 30 m in patients with subacute stroke

International Journal of Rehabilitation Research · 2025
被引 3 · 同刊同年前 6%
ABS 3

中文导读

研究了29名亚急性脑卒中患者,发现15米版本的6分钟步行试验与标准30米版本相比,具有出色的信度和效度,能可靠预测步行距离,适合空间有限的临床环境。

Abstract

The 6-min walk test (6MWT) is used to assess gait capacity in patients with stroke; however, the standard 30-m version (6MWT-30 m) is often impractical in clinical settings because of space limitations. We investigated the validity and reliability of a 15-m version (6MWT-15 m) in 29 individuals with subacute stroke. Test-retest reliability was assessed using the intraclass correlation coefficient (ICC), minimal detectable change (MDC), and Bland-Altman analysis. Validity was evaluated through correlations with the 10-m walk test (10mWT), Berg Balance Scale (BBS), and Fugl-Meyer Assessment for the Lower Extremities (FMA-LE). The 6MWT-15 m demonstrated excellent reliability (ICC = 0.997) and acceptable measurement error (MDC = 19.5 m), with strong correlations with the 10mWT, BBS, FMA-LE, and 6MWT-30 m, supporting its validity. Regression analysis identified the 6MWT-15 m as the sole significant predictor of 6MWT-30 m ( R2 = 0.98) walking distance. These findings support the 6MWT-15 m as a reliable, valid, and practical alternative for assessing walking capacity in patients suffering from subacute stroke, particularly in space-limited clinical settings.